Eberspracher Airtronic D5 Service Manual Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 148
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
PRODUCT INFORMATION | 51
3 | AIRTRONIC: CONTROL UNITS
1
2
3
4
5
6
7
8
9
10
11
12
13
AIRTRONIC: CONTROL UNITS
Model Mini controller Airtronic EasyStart T timer EasyStart R radio remote control EasyStart R
+
radio remote control Calltronic* telephone remote control
Order number 22 1000 32 0700 22 1000 32 8800 22 1000 32 8500 22 1000 32 8000 22 1000 33 8200
ACCESSORIES
Water heater ON/OFF switch 25 1380 89 0400 25 1380 89 0400 25 1380 89 0400
Receiver holder 22 1000 51 2100 22 1000 51 2100
Room temperature sensor (for air
heaters for control during fresh-air
mode) 22 1000 32 4900 No Part of the standard supply
EasyStart T console 22 1000 51 3200
Properties/features
Start heater – heating/venting mode,
turn heater off
Change between heating and
ventilation modes, alter the nominal
temperature preset
Heating/venting ON/OFF, auxiliary unit
ON/OFF, program/delete time presets,
adjust heating stage – for water/air
heaters
Heating/venting ON/OFF, change
operating time permanently
Adjust day of the week, time and
operating time, heating/venting ON/OFF,
auxiliary unit ON/OFF, program/delete
time presets,
adjust heating output
Heating ON/venting ON, heating OFF/
venting OFF, preset/program heating
ON (one in 24h, only possibly by SMS),
enable venting ON (summer mode),
disable venting ON (summer mode)
Description
Controlling room temperature with
Airtronic air heaters
For installation in vehicle interior, new
intuitive menu guidance for user
Basic model, can be combined with
EasyStart T
Comfort version, contains all EasyStart
T functions
Parking heater can be operated by
mobile or landline phone (tone dialling
Preset
Memory capacity for 3 time presets
within 7 days No
Memory capacity for 3 time presets
within 7 days Once in 24 h, only possibly by SMS
Autom. heating time calculation in
preset mode Optional No Yes
No
Run-time immediate operation 10 – 120 minutes, adjustable 20, 30, 40 or 60 minutes, adjustable 10 – 120 minutes, adjustable 10 – 120 minutes, adjustable
Parking ventilation Yes Optional Optional Yes Yes
Temperature display No Optional No Yes No
Feedback Yes Heater status Data transfer successful, heater status Data transfer successful, heater status Input confirmation
Range up to 1 km, under ideal conditions up to 1 km, under ideal conditions
unrestricted (when network coverage
available)
Display
LED display e,g, for time, heating time,
temperature in the vehicle, lighting
coupled to vehicle lighting two-colour LED
LED display e.g. for time, heating time,
heating/venting, battery status
No
Combination options
EasyStart T:
The timer with connected heater
cable loom (universal version) and the
connected diagnosis lead (blue/white)
takes on the master function; instead
of the diagnosis lead (blue/white) it is
also possible to connect up a room or
outside temperature sensor for master
detection (cf. circuit diagram in the
Technical Description)
EasyStart T:
The diagnosis lead (blue/white) must be
connected to the EasyStart T (master);
alternatively, a room or outside
temperature sensor can be connected
to the timer for master detection
(see circuit diagram in the Technical
Description)
EasyStart T:
The receiver of the R
+
with the
connected heater cable loom (universal
version) and the connected diagnosis
lead (blue/white) takes on the master
function; to this end, the room
temperature sensor included in the
scope of supply of the R
+
must be
connected to the receiver of the R
+
(see circuit diagram in the Technical
Description)
Mini controller:
No provision is made for combination
with control units of the EasyStart
family (cf. circuit diagram in the
Technical Description)
Permissible heater combinations with
a control unit Calltronic (see Calltronic)
Unit 1 connected to diagnosis lead, air
heater with JE diagnosis (control boxes
with second diagnosis lead)
Unit 1 connected to diagnosis lead, air
heater with JE diagnosis (control boxes
with second diagnosis lead)
PERMISSIBLE COMBINATIONS OF CONTROL UNITS*
Mini controller
AIRTRONIC Control unit
Mini controller
& EasyStart R EasyStart T
EasyStart T &
EasyStart T
EasyStart T &
EasyStart R
EasyStart T &
EasyStart R
+
EasyStart R
+
Airtronic**
limited: without
venting function
D8 LC
* For other combinations between older heaters and/or older control units, please refer to the corresponding Technical Descriptions for the heater
respectively control units
** D2, D3, B4, D4, D4 Plus, B5, D5
Page view 50