64 | PRODUCT INFORMATION
Airtronic
Airtronic M
Airtronic L
Air heater 8 L / V 7 S
Hydronic / Hydronic 2 / Hydronic 2 C
Hydronic M
Hydronic L
Order No.
suitable for unlimited use ~ suitable for limited use
6 | WATER SYSTEM PARTS
GENERAL INFORMATION:
Mount the water pump below the heater or at the most on the same level.
All water system parts must always remain below the cooling water level of
the engine.
When installing a water heater, always only use water hoses permitted in
automotive engineering as otherwise there is a risk of them bursting or of
pieces of hose coming apart layer by layer, which would clog the water
circuit.
Always use hose clips to fasten water hoses at connection points.
Always route the water hoses so that they are not in contact with or cannot
by worn through by any moving parts. Pay special attention to the extreme
vibrations of an engine when it starts or stops.
Always route the water hoses with large radii to rule out any risk of kinking,
and avoid any freely vibrating water hoses.
Protect the water hoses from extreme heat exposure or even contact with
hot parts of the engine, e.g. with the exhaust pipe.
Always vent the whole water circuit system of a vehicle every time after you
have intervened in the installation.
Please also comply with the safety instructions for this chapter in the heater
documentation.