Eberspracher Airtronic D2 Operations Instructions Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
17
Parts list
1.1 Burner motor
1.2 Glow plug
1.5 Overheating sensor and flame sensor
2.1 Controller
2.2 Dosing pump
2.7 Main fuse
12 volt = 20 A; 24 volt = 10 A
2.7.1 Fuse, actuation 5 A
5.1 Battery
a) Connect the control elements and external temperature
sensors according to the Control Elements
circuit diagram
rt Supply plus terminal 30
ge Switch-on signal S+
gr Temperature actual value
wsrt Switch off theft warning system
br Supply minus terminal 31
blws Diagnosis
grrt Temperature target value
brws Connection to earth for external temperature
sensor and temperature target value
b) Optional
Fresh-air blower
and / or
separate fresh air fan
Cable ends that are not being used must be isolated.
Plug and socket case are shown from the cable entry side.
Cable colours
sw = black
ws = white
rt = red
ge = yellow
gn = green
vi = violet
br = brown
gr = grey
bl = blew
li = purple
Page view 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 31 32

Comments to this Manuals

No comments