26
Removing the cover from the AIRTRONIC
(see picture 1)
Unlock both seal plates, lift cover and take up to the front.
Note:
The cover must always be removed from the
AIRTRONIC
for all repair stages.
You may have to wait for the device to cool down.
Cable harness exit out of the harness either left or right.
1.
2.
Fig. 1
Cover
Seal plates
Removing the controller (see fig. 2)
Remove the
AIRTRONIC
cover (see fig. 1).
Unscrew fastening screw, press retaining brackets
together, lift out the controller. Unclip the lines from the
holder of the controller (observe the positions of the lines).
Withdraw the bushing (lower part) from the outer case.
Disconnect the controller from the controller. The
controller can now be removed.
Note:
When reassembling the controller, ensure that the lines
are correctly clipped in the holder of the controller, and
that the connectors are plugged into the controller (non-
interchangeable).
Tightening torque for the fastening screw no. : 2
+0.2
Nm
햳햴
Fig. 2
Fastening screw
Retaining brackets
Controller
Bushing
Checking the controller
A test instrument is necessary to check the controller in
dismantled state. The test instrument is connected up to
the PC and tests the controller with an installed test
programme.
Order no. test instrument ------
The test instrument is currently
in preparation