Removing the combustion chamber
Remove the cover from the
AIRTRONIC
(see fig. 1).
Remove flange seal.
Take
AIRTRONIC
out of the outer case (lower part).
Remove controller (see fig. 2)
Remove glow plug (see fig. 3)
Remove combustion air blower (see fig. 8).
Unscrew the fastening screws.
For
AIRTRONIC
D2 = 3 fastening screws
For
AIRTRONIC
D4 = 4 fastening screws.
Pull the combustion chamber out to the front and remove
the seal from the heat exchanger.
Note!
When reassembling the combustion chamber, the seal,
which has been enclosed with the spare part, must
always be replaced.
Tighten the fastening screws of the combustion chamber
with a torque of 5
+0.5
Nm.
Note:
If the heat exchanger is being replaced, the combi-sensor
(overheating sensor / flame sensor) must be dismantled
and mounted to the new heat exchanger (see page 28
and 29).
Drawing 6
Combustion chamber
Seal between combustion chamber and
heat exchanger must always be replaced
Heat exchanger
Fastening screws
AIRTRONIC
D2 = 3 fastening screws
AIRTRONIC
D4 = 4 fastening screws
Fig. 9
Combustion chamber
Heat exchanger
Fastening screws
AIRTRONIC
D2 = 3 fastening screws
AIRTRONIC
D4 = 4 fastening screws