29
Electrical system5
Parts list for the circuit diagrams
Parts list for the circuit diagrams for the control
elements
2.15.1 Temperature sensor (room temperature)
2.15.9 Temperature sensor (outside temperature)
3.1.9 “Heating / ventilation“ selector switch
3.1.16 Radio remote control button
3.1.17 AIRTRONIC mini controller
3.1.18 CALLTRONIC button
3.2.8 Module timer (ADR – potentiometer)
3.2.12 Timer, mini – 12 / 24 volt
3.2.14 Lighting, mini timer – 12 volt only
3.3.6 Radio remote control stationary part TP41i
3.3.7 Radio remote control stationary part TP5
3.3.8 CALLTRONIC remote control
3.8.3 Antenna
3.9.1 Diagnosis, JE diagnosis
a) Connection control elements to the AIRTRONIC
• rt Power supply, plus – terminal 30
• ge Switch-on signal – S+
• gr Temperature – actual value
• wsrt Switch off burglar alarm (ADR–
feedback for timer)
• br Power supply, minus – terminal 31
• blws Diagnosis
• grrt Temperature – setpoint
• brws Ground connection for external
temperature sensor and temperature
setpoint
b) Terminal 15 – necessary for TP4i connection
c) Lighting, terminal 58
d) Connection, diagnosis device
e) Connection, external temperature sensor
g) Connection, external heating button
h) Connection, radio remote control TP4i
j) Connection, temperature sensor (outdoor
temperature)
l) Connection, “heating / ventilation“ selector switch
(option). To start: Set the “heating / ventilation“
selector switch then switch the AIRTRONIC on.
z) Lighting, terminal 58
Cable colours
sw = black
ws = white
wsrt = white / red
rt = red
ge = yellow
gn = green
vi = violet
br = brown
brws = brown / white
gr = grey
grrt = grey / red
bl = blue
blws = blue / white
li = purple
• Insulate unused cable ends.
• Connectors and bush housings are shown from the
cable entry side.
Please note!
Comments to this Manuals