Dismantling the heat exchanger
Removing the combustion air blower
Remove the
AIRTRONIC
cover (see fig. 1)
Remove the controller (see fig. 2)
Remove the flange seal.
Take the
AIRTRONIC
out of the outer case (lower part).
Unscrew the 4 fastening screws from the combustion air
blower.
Remove the combustion air blower and the seal from the
heat exchanger.
Important!
When reassembling the combustion air blower, a new
seal is always required.
Tighten the 4 fastening screws of the combustion air
blower in the series shown in the drawing, with
a tightening torque of 4
+0.5
Nm.
Fig. 8
Combustion air blower
Heat exchanger
Fastening screw
Drawing 5
Tighten the fastening screws in this sequence
with a tightening torque of 4
+0.5
Nm
Always replace the seal between combustion air blower
and heat exchanger