14 | PRODUCT INFORMATION
EBERSPÄCHER HYDRONIC
Heater Hydronic L16 Hydronic L24 Hydronic L30 Hydronic L35
Scope of supply Heater Heater Heater Heater
Technical designation Hydronic L-II (HL2-16) Hydronic L-II (HL2-24) Hydronic L-II (HL2-30) Hydronic L-II (HL2-35)
Order No. Heater 25 2486 02 00 00 25 2487 02 00 00 25 2488 02 00 00 25 2489 02 00 00
Order No. Heater Compact
— 25 2487 05 00 00 25 2488 05 00 00 25 2489 05 00 00
Fuel Diesel Diesel Diesel Diesel
Voltage V 24 24 24 24
Heating medium Water Water Water Water
Heating output W 16,000 24,000 30,000 35,000
Fuel consumption l/h 2 2.9 3.65 4.2
Electr. power consum. Operation W 60 80 105 120
Minimum water flow rate l/h 1,400 2,000 2,600 3,000
Lower voltage limit V 20 20 20 20
Upper voltage limit V 30 30 30 30
Interference suppression class 4 for VHF / SW / LW, 5 for MW 4 for VHF / SW / LW, 5 for MW 4 for VHF / SW / LW, 5 for MW 4 for VHF / SW / LW, 5 for MW
Dimensions L x W x H mm 600 x 230 x 222 600 x 230 x 222 600 x 230 x 222 600 x 230 x 222
Empty weight** kg 18 18 18 18
EBERSPÄCHER WATER
PUMPS FOR HYDRONIC
Water pumps Flowtronic 5000* Flowtronic 5000 S Flowtronic 6000 SC
Order No. Water Pump 25 2488 26 00 00 25 1818 30 00 00 25 2488 25 00 00
Coolant liquid
Water-glycol mixture with
up to max. 50% glycol share
Water-glycol mixture with
up to max. 50% glycol share
Water-glycol mixture with
up to max. 50% glycol share
Flow rate at 0.2 bar delivery
pressure l/h 5,200 5,200 6,000
Operating pressure bar max. 2 max. 2 max. 2
Rated voltage V 24 24 24
Electrical power consumption W 104 104 210
Degree of protection IP5K4 IP54A IP25 (sealed electronic component)
Dry running no no yes – motor turns off after 45 min
Shaft – impeller connection Mechanical seal Magnetic clutch Magnetic clutch
Empty weight** kg 2.04 2.2 2.5
* available from week 5 / 2012
** without holder, clamp and coolant liquid
1
2
3
4
5
6
7
8
9
10
11
12
13
Comments to this Manuals