32 | PRODUCT INFORMATION
3 | AIRTRONIC: SELECTION OF THE AIR HEATER
ø 75 mm
Test: Scope of hot air system
(length, number of elbows, outflows etc.)
Which guide number** is needed?
GUIDE NUMBER≤ 3 ≤ 10
Airtronic D4
+
Universal-ES (ø 75)
Airtronic D4 Plus
+
Universal-ES (ø 75)
or
installation kit Plus* (ø 75)
Alternative***: Airtronic D3
Heating output demand 4,000 W
Test space demand Airtronic D4
OK
Test space demand for hot air system
Decision for 90 mm or 75 mm ø air supply
ø 90 mm
Test: Scope of hot air system
(length, number of elbows, outflows etc.)
Which guide number** is needed?
GUIDE NUMBER≤ 15 ≤ 10
Airtronic D4 Plus
+
Universal-ES (ø 90)
or
installation kit Plus* (ø 90)
Airtronic D4
+
Universal-ES (ø 90)
or
installation kit Plus* (ø 90)
Alternative***: Airtronic D3
1
2
3