10 | EXHAUST SYSTEM / COMBUSTION SYSTEM PARTS
GENERAL INFORMATION:
The combustion air system is to be fitted so that
the connection at the heater fitting is tight.
the pipe mouth never faces into the head wind.
as far as possible, no water can splash into the pipe mouth, or otherwise
runs out again immediately without penetrating into the heater.
no exhaust fumes from the heater or vehicle engine can be sucked into the
system.
Please also comply with the safety instructions for this chapter in the heater
documentation.
Installing the exhaust system:
Exhaust pipes should always slope down to the pipe mouth.
If this is not possible, a hole must be provided for water to drain at the
lowest point.
If this point is not on the outside (e.g. boat machine room), this opening
must be connected directly with a so-called overflow vessel.
Constrictions in the cross-section of the exhaust pipe compared to the
exhaust connection at the heater must be avoided at all costs.
Please refer to the Technical Description and installation instructions for
permitted lengths, diameters and bends in the combustion air and exhaust
pipes.