Installation3
Combustion air system
Installing the combustion air system
The universal installation kit includes a combustion air
silencer, which must be fitted.
If necessary, the combustion air system can be
lengthened up to max. 2 m using a connector and a
flexible combustion air hose, internal Ø 25 mm (please
refer to the additional parts catalogue for the order
no.).
Fix the combustion air silencer to the heater using a
pipe clip and use a hose clip to fix at a suitable point.
• The combustion air silencer must always be installed.
Comply with the regulations and safety instructions
for this chapter given on page 4 – 7.
Please note!
Caution!
Safety instructions for the combustion air system!
• The combustion air opening must be free at all times.
• Lay the combustion air intake to ensure that exhaust
fumes cannot be sucked in as combustion air.
• Do not point the combustion air intake against the
vehicle’s airstream.
• The combustion air intake must not become clogged
with dirt and snow.
• Install the combustion air system sloping slightly
downwards. If necessary, make a drain hole approx.
Ø 5 mm at the lowest point as a condensation outlet.
1 Combustion air silencer
2 Connection pipe, optional
3 Combustion air silencer, optional
4 Flexible exhaust pipe, di = 24 mm
5 Exhaust silencer, optional
6 Exhaust end pipe with end sleeve
7 Hose clip
8 Combustion air pipe connection
9 Exhaust connection
max. 2 m
min. 0.2 m
max. 2 m